10. Options
Start Duration
Sets the minimum track length in seconds for auto
recording. Tracks that are shorter than this value are
automatically deleted.
Stop Level
Defines the auto recording stop threshold level in dB. When
the input audio level falls below this value, recording
provisionally stops.
Stop Duration
Sets the period of time that the input audio level must stay
below the stop threshold level to complete the end of an
auto recording. This value is in seconds.
Service Names
You can give names to the particular recording channels for
easier identification These names are displayed on the
record, archive and play screens and will also be stored in
the MPEG BWF or G.729A header of an archive or download
file.
Note that once recording has started on a channel, the
record format cannot be changed until recording has
stopped and all track/s have been deleted.
Record Capacity
The slide bar at the bottom of the record options screen
allows you to select the hard drive partition size for each
input. The partition size is the amount of space allocated to
each input for storing audio. The bigger the partition the
more space is available, allowing for longer recordings. If an
Audio Input is set to Mono (Dual), each mono channel will
share equally the space allocated for that input.
The duration of the audio recorded to each partition is
calculated and displayed. To change the duration for a fixed
partition size using MPEG as the record format, the Bit Rate
should be set to a new value. A lower Bit Rate means a
longer duration and, conversely, a higher Bit Rate means a
shorter duration.
Archive
This screen (
Figure 10.2
) displays the current settings for
archiving from the Net-Log. See Chapter 7 for more detailed
information.
Alarm Enabled
Allows data loss warnings and alarms to be disabled.
Buffer Size (Mbytes)
Amount of data that has to be available before archiving can
start.
Warn time prior to data loss
Amount of time prior to data loss occurring that a warning is
activated.
Arrange Archive Audio into Fixed Duration Files
Formats the archived audio into fixed duration files.
Target File Duration (mins)
The length of the target files. (5 - 60 minutes)
Target File Type
The type of files that are created. The options available for
this setting will change depending on the record format
selected for this channel.
Figure 10.2 Archive Options
Sonifex Net-Log-Win User Handbook
32
Summary of Contents for Net-Log
Page 1: ...Sonifex Net Log User Handbook...
Page 6: ...Contents Sonifex Net Log User Handbook...
Page 10: ...License Form Sonifex Net Log User Handbook 4...
Page 16: ...1 Introduction Sonifex Net Log User Handbook 10...
Page 24: ...3 Net Log Set up Installation Sonifex Net Log User Handbook 18...
Page 32: ...5 Recording Sonifex Net Log User Handbook 26...
Page 36: ...6 Playing Downloading Sonifex Net Log Win User Handbook 18...
Page 48: ...9 Serial Control Interface Sonifex Net Log Win User Handbook 30...
Page 56: ...11 The Administrator Sonifex Net Log Win User Handbook 38...
Page 62: ...13 Technical Specification Sonifex Net Log Win User Handbook 44...
Page 64: ...14 Glossary Sonifex Net Log Win User Handbook 46...