13. Technical Specification
Sonifex Net-Log-Win User Handbook
42
Hard Disk Capacity:
A minimum hard-disk size of 200GB is fitted. Due to the rapidly increase of
disk capacities, the actual hard disk installed may be larger than this. The
following tables show the capacity in duration for the different record formats.
If more than one channel is used then the duration will need to be shared.
MPEG Data Rate in
kilobits per second
(kbps)
Record Duration per Gigabyte of
Hard Disk Space in
Days.Hours.Minutes
8
11d 13h 46m
16
5d 18h 53m
24
3d 20h 35m
32
2d 21h 26m
40
2d 7h 33m
48
1d 22h 17m
56
1d 15h 40m
64
1d 10h 43m
80
1d 3h 46m
96 23h
8m
112 19h
50m
128 17h
22m
MPEG Data Rate in
kilobits per second
(kbps)
Record Duration per Gigabyte of
Hard Disk Space in
Days.Hours.Minutes
144 15h
25m
160 13h
53m
192 11h
34m
224 9h
55m
256 8h
41m
320 6h
56m
384 5h
47m
G.729A Data Rate in
kilobits per second
(kbps)
Record Duration per Gigabyte of
Hard Disk Space in
Days.Hours.Minutes
9.6 (fixed)
9d 15h 28m
Pin Connections
COM 1/2 (9 Pin D-Type Plug):
Pin No.
Signal
Direction
Description
1 CD
I Carrier
Detect
2 Rx
I Receive
Data
3
Tx
O
Transmit Data
4
DTR
O
Data Terminal Ready
5 SG
- Signal
Ground
6
DSR
I
Data Set Ready
7
RTS
O
Request To Send
8
CTS
I
Clear To Send
9 N/C
- No
Connection
Alarm Outputs/Remote Inputs (15 Pin D-Type Plug):
Pin No.
Signal
Direction
Description
1 Relay
Common
O
Alarm Output Relay Common
2
Relay N/C
O
Alarm Output Relay N/C to Pin 1 activates for both Archive and Hard Disk
Alarms
3
Relay N/O
O
Alarm Output Relay N/O to Pin 1 activates for both Archive and Hard Disk
Alarms
4 Relay
Common
O
Alarm Output Relay Common
5
Relay N/C
O
Alarm Output Relay N/C to Pin 4 activates for both Archive and Hard Disk
Alarms
6
Relay N/O
O
Alarm Output Relay N/O to Pin 4 activates for both Archive and Hard Disk
Alarms
7 GND - Ground
8
REMOTE_I1
I
Remote Input 1 short to Ground (Remote record Channel 1, Left input 1). Set
to momentary or latching action via the Options, Record Remotes screen.
9
REMOTE_I2
I
Remote Input 2 short to Ground (Remote record Channel 2, Right input 1) Set
to momentary or latching action via the Options, Record Remotes screen.
10
REMOTE_I3
I
Remote Input 3 short to Ground (Remote record Channel 3, Left input 2) Set to
momentary or latching action via the Options, Record Remotes screen.
11
REMOTE_I4
I
Remote Input 4 short to Ground (Remote record Channel 4, Right input 2) Set
to momentary or latching action via the Options, Record Remotes screen.
12
REMOTE_I5
I
Remote Input 5 short to Ground (Not used in V1.00 software)
13
REMOTE_I6
I
Remote Input 6 short to Ground (Not used in V1.00 software)
14
REMOTE_I7
I
Remote Input 7 short to Ground (Not used in V1.00 software)
15
REMOTE_I8
I
Remote Input 8 short to Ground (Not used in V1.00 software)
Summary of Contents for Net-Log
Page 1: ...Sonifex Net Log User Handbook...
Page 6: ...Contents Sonifex Net Log User Handbook...
Page 10: ...License Form Sonifex Net Log User Handbook 4...
Page 16: ...1 Introduction Sonifex Net Log User Handbook 10...
Page 24: ...3 Net Log Set up Installation Sonifex Net Log User Handbook 18...
Page 32: ...5 Recording Sonifex Net Log User Handbook 26...
Page 36: ...6 Playing Downloading Sonifex Net Log Win User Handbook 18...
Page 48: ...9 Serial Control Interface Sonifex Net Log Win User Handbook 30...
Page 56: ...11 The Administrator Sonifex Net Log Win User Handbook 38...
Page 62: ...13 Technical Specification Sonifex Net Log Win User Handbook 44...
Page 64: ...14 Glossary Sonifex Net Log Win User Handbook 46...