24
9 Matching Converters - RB-PLI6
Rear Panel Connections and Operation
Fig 9-3: RB-PLI6 Rear Panel
Inputs
dŚĞƌĞĂƌĞϲŽĨĨy>ZϯƉŝŶƐŽĐŬĞƚŝŶƉƵƚƐ͘dŚĞLJŚĂǀĞƚŚĞĨŽůůŽǁŝŶŐ
connections:
Pin 1: Screen
Pin 2: Phase
Pin 3: Non-phase
Outputs
dŚĞƌĞĂƌĞϲŽĨĨy>ZϯƉŝŶƉůƵŐŽƵƚƉƵƚƐ͘dŚĞLJŚĂǀĞƚŚĞĨŽůůŽǁŝŶŐĐŽŶŶĞĐƚŝŽŶƐ͗
Pin 1: Screen
Pin 2: Phase
Pin 3: Non-phase
Outputs
Inputs
Ground-link Internal Jumpers
The unit has jumpers that are used to balance either the input, or the
output, about ground. By default these are not fitted when the unit leaves
the factory.
To get inside the RB-PLI6, observing anti-static precautions, undo the four
crosshead screws on the back panel at the far left and far right of the panel
(2 at each end). Also undo the small brass screws, which hold the top and
bottom panels to the rear panel. The rear panel should slide backwards out
of the unit together with the main circuit board.
Fig 9-4: RB-PLI6 Ground-link Jumper Settings