MP5 Plus Writer Easy Guide
SONIX TECHNOLOGY CO., LTD.
Page 33
Version 1.0
Remark
1. Can select different modes through the "MODE".
2. Checksum:
If the security is enable, it is Security checksum;
If the security is disable, it is EPROM checksum.
3. Rolling Code
:
If Rolling Code is used,
The lowest Word value for Rolling Code is displayed in FUN0, FUN2, and FUN6.
MCU’s checksum is displayed first, followed by the lowest Word value for Rolling Code in FUN4.
4. Fun8 can view the machine code, Press Enter again can look up MCU type and firmware version;
Such as:
“17PY3462”, machine code;
“SN8P2501B-F5101”, “SN8P2501B” is MCU type, “F5101” is the firmware version.
Table4-1 Functions and descriptions in off-line mode
Alarm information description of each operation function is shown in table4-2 below:
Item
Error message
Description
1
Err0
Programming voltage fail
2
Err1
Blank check fail
3
Err2
Program fail
4
Err3
Verify fail
5
Err4
Read Flash fail
6
Err5
Read CHIP ID fail
7
Err6
MCU not be found
8
Err9
Feedback signal fail
9
ErrA
Read IHRC data fail
10
ErrB
Adjust IHRC fail
11
ErrC
Recheck IHRC fail
12
ErrD
Program IHRC fail
13
ErrE
Verify IHRC Data fail
14
ErrF
The programming file’s checksum fail
15
Er10
Check checksum fail
16
Er11
No use Rolling Code
17
Er30
The number of programming set was exceeded
18
Er40
Read machine code fail
Table4-2 Alarm information description in off-line mode