3 | Product description
8 / 20
Operating instructions sonnenProtect 1300
3 Product description
3.1 Technical data
sonnenProtect 1300
System data
Maximum power (2 sec.)
2,200 W
Nominal power
1,300 W
Output voltage (AC)
230 V +/- 10 %
Nominal frequency
50 Hz
Network configuration in emergency opera-
tion
IT
Operating concept
Single-phase power supply via plug outlet. The
switch to emergency operation takes place
automatically through the storage system.
Switchover time to emergency operation
approx. 5 seconds
Dimension/Weight
Dimensions (H/W/D) in mm
235/150/124
Weight in kg
approx. 2 kg
Safety
Protection class
I (PE conductor)
Degree of protection
IP21
Overvoltage category
III
Protective functions
Overcurrent protection, insulation monitor
(as per IEC 61557-8)
Ambient conditions
Environment
indoor (conditional)
Ambient temperature range
5 °C ... 30 °C
Storage temperature range
0 °C ... 40 °C
Transport temperature range
-15°C ... 30 °C
Max. rel. humidity
90 %, non-condensing
Permissible installation altitude
2,000 m above sea level
Pollution degree
2
Additional ambient conditions
The ambient conditions prescribed for the
storage system apply.
Table 2: Technical data