47
3. Installation
A mounting bracket is provided with the heater. The bracket
has been specifically designed to allow the product to be
fitted to a ceiling. Before drilling the holes for the ceiling
mount, please ensure that the surface is solid and that
there are no hidden water pipes or electrical wires. The
heater must be installed no less than 50 cm from any side
walls and no less than 2.4 m from the floor.
Warning:
The appliance must be installed on solid surfaces
such as concrete, wood or metal, etc.
Important:
Please ensure that the supply cable is well secured so that it does not come into contact
with the reflector or trail into the heated area. The supply cable can be fixed to the metal mounting
bracket behind the heater with plastic zip ties.
1.
This heater should be installed by a competent person, i.e. a qualified electrician.
2. Always disconnect the heater from the electrical supply and allow it to cool before installation.
3. When mounting on a ceiling, the lowest part of the heater must be located at or above a minimum
height of 2.4 m from ground level so that the heater cannot be touched when in operation.
4. When mounting on a ceiling, there must be a distance of 2.4 m between your appliance and the
floor.
5. When mounting on a ceiling, there must be a distance of 0.5 m between any side walls and the
appliance.
6. There must be a minimum distance of 1 m between your appliance and any living beings.
7.
There must be a distance of at least 1 m between the front side of the heater and materials such as
wood, cardboard or cloth, etc.
8. When mounting on a ceiling, do not position the heater at an angle more than 90° or less than 45°.
9. The supply cable must be at the lower end of the heater if the heater is installed at an angle or
vertically.
10. Keep the supply cord away from the body of the heater, which will get hot during use.
11. Do not install the heater on an inflammable surface.
12. Observe the minimum safe distance between the heater body and the inflammable surfaces when
mounted.
13. The heater should always have a minimum clearance of 0.5 m from the ceiling and adjacent walls.
14. If the heater is to be used outside, a weatherproof outlet is recommended.
15. Before drilling, ensure that there are no wires or water pipes in the area where the heater is to be
installed.
16. The heater must be installed on the mounting brackets provided.
17. Fasten the brackets securely to the mounting surface and to the back of the heater using the fittings
supplied.
18. Fasten the heater securely onto the brackets using the fittings supplied.
19. The brackets can be used to adjust the direction of the heater. Adjust the heater angle by loosening
the two bolts on the ceiling-mounting bracket and tighten the bolts again when the desired angle