62
Instruction for use | Supercal 5
13.4 Technical Data flow sensor Superstatic 440
qp
Threaded
connection
Flanged
connection
Length
Mat.
PN
Maximal
flow qs
Minimal
flow qi
Low flow thres
-
hold value
(50°C)
Threaded
hole for
sensor
Weight
(*) (**)
Kvs value
(at 20°C)
Pressure
loss at
qp
m
3
/h
G"
DN
mm
PN
m
3
/h
l/h
l/h
kg
m
3
/h
bar
(EN ISO
228-1)
(ISO 7005-3)
1
3/4"
(15)
110
Brass
16/25
2
10
4
Yes
2,9
2,09
0,20
1
1"
(20)
190
Brass
16/25
2
10
4
Yes
3,2
2,09
0,20
1,5
3/4"
(15)
110
Brass
16/25
3
15
10
Yes
2,9
2,06
0,25
1,5
1"
(20)
190
Brass
16/25
3
15
10
Yes
3,2
5,44
0,09
2,5
1"
(20)
190
Brass
16/25
5
25
10
Yes
3,2
5,21
0,25
3,5
1 1/4"
(25)
260
Brass
16/25
7
35
15
Yes
3,5
7,46
0,16
3,5
25
260
Brass
16/25
7
35
15
5,4
7,46
0,16
6
1 1/4"
(25)
260
Brass
16/25
12
60
30
Yes
3,5
13,4
0,16
6
25
260
Brass
16/25
12
60
30
5,4
13,4
0,16
10
2"
(40)
300
Brass
16/25
20
100
50
Yes
4,5
20,9
0,25
10
40
300
Brass
16/25
20
100
50
8
20,9
0,25
(ISO 7005-1)
15
50
270
SS/CI
16/25
30
150
75
9,1
31,6
0,25
25
65
300
SS/CI
16/25
50
250
125
11,2
51,8
0,25
40
80
225
SS
16/25
80
800
400
14,4
142
0,09
40
80
300
SS/CI
16/25
80
800
400
13,1
142
0,09
60
100
250
SS
16/25
120
1,200
600
NA
210
0,10
60
100
360
SS/CI
16/25*
120
1,200
600
19
210
0,10
100
125
250
SS/CI
16/25*
200
2,000
1,000
NA
343
0,10
150
150
300
SS/CI
16/25*
300
3,000
1,500
27,2
514
0,10
150
150
500
SS
16/25
300
3,000
1,500
NA
514
0,10
250
200
350
SS
16/25
500
5,000
2,500
NA
857
0,10
400
250
450
SS
16/25
800
8,000
4,000
38,1
1,372
0,10
SS=Stainless Steel; CI=Spheroidal cast iron, *: PN 25 only SS
(*) Weight Value indicated only for the heaviest material.
(**) Weight corresponding only for the flowmeter with 3mts cable.
NA : not available
m
3
/h
m
3
/h
m
3
/h
800
350
500
Steel
10/16
1,600
32
16
90/105
2,667
0,10
1,500
500
500
Steel
10/16
3,000
60
30
130/195
5,000
0,10
Coated Steel
The flow sensor Superstatic 440 can be operated from 0.5 bar pipe pressure. To prevent cavitation
the operating pressure with a flow sensor Superstatic 440 must follow the recommendation in
the table below. The Superstatic 440 must not be exposed to pressures below ambient pressure.
Flow
Static pressure (bar)
q
% qp
T= 80°C
T= 130°C
qi (qmin)
1
1.0
3.3
qp
100
15.
4.0
qs
200
3.0
6.0