C905
1222-9526 rev. 1
TROUBLESHOOTING
TROU
B
L
E
S
H
O
OTIN
G
Equipment List
Connection Instructions for the Dummy Battery
This is the correct setup when using the Dummy Battery.
See Pictures 12 and 13.
Picture 12
Picture 13
Customized FM Radio Cable
Step 1:
Use the Test lead BNC-4mm 1,5m Cable, see Picture 14.
Picture 14
Product Name: Test lead BNC-4mm 1,5m
Product Description: Test lead with 4 mm lab plugs at one end and a BNC plug at the other.
Manufacturer: PMK Germany
Location:
http://www.elfa.se/en/
or other supplier.
Part number: 46-310-40
Note! This is the ELFA part number.
Step 2:
Cut the Red Lab Plug connector according to Picture 15.
Picture 15
Step 3:
Use any Hands-Free (PHF) Cable and cut it according to Picture 16.
Picture 16
Note! Cable length should be at least 40 cm.
Step 4:
Only use the Wire that is connected to PIN2 and cut out all others according to Picture 17.
Picture 17
Note! Use DMM instrument to ensure which of the wires are connected to PIN2 at Hands-Free
(PHF) system connector plug.
SEMC Troubleshooting Manual
6
(124)