2-2-3.
Main Code 96
When an internal calendar clock error is detected, the following error occurs.
Main
code
Sub code
(1)
Sub code
(2)
Error message
Description
96
01
00
CALENDAR CLOCK
ERROR
An internal calendar clock error was detected.
• Probable cause 1: IC110 or BT101 (lithium bat-
tery) on SY-422A board
• Probable cause 2: IC1 (SYS1 CPU) on SY-422A
board
• Protected operation: None
2-2-4.
Main Code B3
Note
If main error code “B3” occurs each time the unit is turned on, contact your local Sony Sales Office/Service Center.
When a trouble was detected in the device initialization process, one of the following errors occurs.
Main
code
Sub code
(1)
Sub code
(2)
Error message
Description
B3
01
00
SY CPLD2 INITIAL ER-
ROR
Initialization error of CPLD2 on SY-422A board was
detected.
• Probable cause: IC1701 on SY-422A board
• Protected operation: None
B3
02
00
SY FPGA1 INITIAL ER-
ROR
Initialization error of FPGA1 on SY-422A board was
detected.
• Probable cause: IC3 on SY-422A board
• Protected operation: None
B3
03
00
SY FPGA2 INITIAL ER-
ROR
Initialization error of FPGA2 on SY-422A board was
detected. (Support in the future)
• Protected operation: None
B3
04
00
SY FPGA NOT LATEST
FPGA on the SY-422A board was not initialized by
latest data, and it was initialized by backup data.
• Probable cause: IC1701 on SY-422A board
• Protected operation: None
B3
11
00
CP CPLD2 INITIAL ER-
ROR
Initialization error of CPLD2 on CP-407A board was
detected.
• Probable cause: IC2801 on CP-407A board
• Protected operation: None
B3
12
00
CP FPGA1 INITIAL ER-
ROR
Initialization error of FPGA1 on CP-407A board was
detected.
• Probable cause 1: IC2001 on CP-407A board
• Probable cause 2: SYS1
• Protected operation: None
B3
13
00
CP BANK INITIAL ER-
ROR
Initialization error of BANK1 block in FPGA1 on
CP-407A board was detected.
• Probable cause 1: IC2001 on CP-407A board
• Probable cause 2: SYS1
• Protected operation: None
B3
14
00
CP FPGA NOT LATEST
FPGA on the CP-407A board was not initialized by lat-
est data, and it was initialized by backup data.
• Probable cause 1: IC2801 on CP-407A board
• Probable cause 2: SYS1
• Protected operation: None
B3
28
00
HP CPLD2 INITIAL ER-
ROR
Initialization error of CPLD2 on HP-160A board was
detected.
• Probable cause: IC11 on HP-160A board
• Protected operation: None
Continued
PWS-4400
2-4