• Adjustment Method of ChgI_H
(item number: 758)
1. In the state of power off, short SL952 on the MAIN board
with a solder bridge. Then, turn on the power.
2. Connect a digital voltmeter to the TP962 (ChgI H) on the MAIN
board, and adjust
[VOL +]
key (voltage up) or
[VOL --]
key
(voltage down) so that the voltage becomes 1.40
±
0.01V.
3. Press the
–
key to write the adjusted value.
4. After adjustment, turn off the power and open the solder bridge
on SL952 on the MAIN board.
Adjustment and Connection Location: MAIN board
(see page 22)
LCD display
**
: adjusted value
C I H * *
758
digital
voltmeter
MAIN board
TP962 (ChgI H)
TP952 (GND)