2-5 (E)
BDX-E1000
2-4. BDKP-E1004/E1005 Installation
Either BDKP-E1004 (SCR-4 board) or BDKP-E1005
(SCR-5 board) can be installed on the SY-240 board which
has board suffix -13 and higher.
Installation procedures
1.
Remove the SY-240 board from the BDX-E1000.
(Refer to the Section 2-1.)
2.
Fix the two PCB holders supplied with the BDKP-
E1004/E1005 to the SY-240 board.
3.
Match the connectors CN301 and CN302 on the SCR-
4/5 board with the connectors CN901 and CN902 on
the SY-240 board.
4.
Connect the connectors on the SCR-4/5 board to the
connectors on the SY-240 board while inserting the
PCB holders through the holes on the SCR-4/5 board.
n
Make sure that the connectors are connected tightly.
5.
Insert the SY-240 board into the Slot No.4. (Refer to
the Section 2-1.)
6.
Install the board retainer with the four screws.
7.
Close the front panel.
8.
Tighten the locking screw.
Confirmation after installation
There is no necessity to confirm/adjust after SCR-4/5
board installing.
SY-240 board
PCB holders
2-4. BDKP-E1004/E1005 Installation
SY-240 board
SCR-4/5 board
CN902
CN302
CN301
CN901
PCB holder
PCB holder