6-10
DNW-7/90/90WS
6-12. H/V Ratio Adjustment (16:9)
6-13. Detail Level Adjustment (16:9)
6-13. Detail Level Adjustment (16:9)
16:9 mode
Note
.
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.
On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: DETAIL
→
ON
ITEM
: TEST OUT
→
ENC
.
Shoot a gray-scale chart (16:9) in the full underscan’s
picture frame.
Setting point
:
1
Lens IRIS
Spec.
: A = 80
±
2 IRE (NTSC)
A = 560
±
14 mV (PAL)
Adjustment procedure
Test point: TEST OUT connector
1.
On the setting menu, adjust as follows.
PAGE
: LEVEL 1
ITEM
: DETAIL LEVEL (Factory setting: 0)
Spec.
: Set to the detail signal which is added
to each step in the gray-scale chart.
A
6-12. H/V Ratio Adjustment (16:9)
16:9 mode
Preparation
.
On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: DETAIL
→
ON
ITEM
: TEST OUT
→
ENC
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot a gray-scale chart (16:9) in the full underscan’s
picture frame.
Setting point
:
1
Lens IRIS
Spec.
: A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
Adjustment procedure
Equipment: Black and white monitor
Test point: TEST OUT connector
1.
On the setting menu, adjust as follows.
PAGE
: LEVEL 1
ITEM
: V DTL LEVEL
Spec.
: Adjust so that the H and V detail
amounts which are added are equiva-
lent.
A
H
V