1-2
FVS-1000 MMP1
1-3. Environmental Conditions
1-3. Environmental Conditions
To use the FVS-1000 safely and to maintain the stable performance in the long term, keep the appropriate
environmental conditions according to the followings.
Especially, as for the strength of the floor where the FVS-1000 is installed, be sure to keep the specified
or more strength.
c
Install the FVS-1000 to the place which has the adequate strength.
If it is installed to the place which does not have the sufficient strength, there is a danger of death or
severe injury with it tumbled.
.
Operating temperature :
10
d
C to 35
d
C (Recommended temperature range: 20
d
C to 25
d
C)
.
Operating humidity :
20 % to 90 % (no dew condensation)
.
Evenness of floor :
5 mm or less
.
Height of ceiling :
500 mm or more from the top of the system
.
Strength of floor :
12 kN/m
2
(1200 kgf/m
2
) or more, 6 kN/point (600 kgf/point) or more
n
The pressure per 1 point is the sum of the pressure by the caster (75 mm (diameter)
x
65 mm (width))and
the adjuster foot (leveler) (80 mm (diameter)).
Do not install the FVS-1000 under the following conditions.
.
Under high temperature or high humidity
.
Near a heat source
.
Dusty
.
Under the place where there is vibration
.
Near the strong electric field or magnetic field