1-8
FVS-1000 MMP1
3. Confirmation of voltage selector
1.
Check the VS-60 board from the slit of the rear panel.
2.
Confirm that the harness is connected with the connector of the used voltage on the VS-60 board.
4. Connection of power supply code
w
Use the specified power supply code.
If the power supply code other than the specified one is used, there is a danger of a fire or an electrical
shock.
When installing the unit, incorporate a readily accessible disconnect device in the fixed wiring, so that the
user can turn off the power in case a fault should occur.
This work may be required by laws of each country. Follow laws of each country.
Specified power supply code
.
600 V VCT cable (3 cores)
Select from the following three codes according to the power consumption.
Size (cross section area)
5.5 mm
2
: 36 A or less
8.0 mm
2
: 44 A or less
14.0 mm
2
: 62 A or less
.
Wire crimp type terminal
6.73 mm
Wire crimp type terminal
VCT cable
Size (cross section area)
17 mm
1-10. Installation Procedure
100V
120V
220~240V
VS-60 board
Rear side
100 V
120 V 220 to 240 V
Harness