2-6 (E)
BKP-5090
2-2-3. INT SC Phase Adjustment
Notes:
This adjustment procedures are stated below assuming that
the Tektronix 1750 (for NTSC) or1751 (for PAL) is used.
If any other measuring instrument is used, follow the
instructions given in the operation manual attached to it.
Equipment
: Waveform/Vector monitor
(SC-H Phase measuring mode)
Test Point
: TEST OUT connector
Preparations:
.
Connect the waveform/vector monitor to the TEST OUT
connector.
.
OUTPUT/DCC switch (on the side panel)
→
BARS
.
RGB/ENC switch (on the side panel)
→
ENC
Adjustment Procedures:
1.
Set the DISP switch (on the side panel) from OFF to
MENU while holding down the MENU SEL switch
(on the front panel).
2.
Set the menu as follows, and adjust the SC-H phase by
using the MENU SEL switch.
MENU
: System config
PAGE
: Y/Chroma (S2)
ITEM
: SC-H Phase
Specification
: Position the luminous lines of the
burst (SC) and the beam spot of H
as shown in the figure.
(
For NTSC)
(For PAL)
File Store:
Execute the file store. Press the MENU SEL switch twice
to execute.
MENU
: Trimming File
PAGE
: Trimming File (T1)
ITEM
: File Store