1-6 (E)
BKP-7090
Replacing the connector panel assembly
(1) Loosen the six screws to remove the connector panel assembly. Disconnect the two connectors.
(2) Install the supplied connector panel assembly in the reverse order of removal.
n
When tightening the screw securing the lug on the right, push the lug to the direction of the BNC
connector as far as it will go and then tighten. If not, the lug is sometimes caught between the plug
and chassis when plugging in the TRACKER connector. This may cause improper connection.
Affixing the UP GRADE label
Close the both side panels. Place the UP GRADE label (supplied with the BKP-7090) as shown in the
figure.
Loosen
Loosen
Loosen
Connector panel assembly
Connector
Connector
Lug
BNC connector
TRACKER connector
1-2. Installing the BKP-7090 in the BVP-700/700P
1
UP GRADE label