1-4
BKS-R3219A/R1617A I&SSM
1-5. Controls by Routing Switcher System
1-5-1. Specifications and Functions of Control Port
The Routing Switcher System has four kinds of remote ports : REMOTE 1 (standard S-BUS), REMOTE
2 (RS-422A), REMOTE 3 (RS-232C), and NETWORK (Ethernet)
*
1
. Among the four remote systems,
BKS-R1617A and BKS-R3219A are equipped with two remote terminals supporting the two remote
systems: REMOTE 1 and REMOTE 2.
*
1 : NETWORK (Ethernet) : IXS-6600/IXS-6700/BKS-R6010
DATA (Ethernet) : HKSP-R80 and HDS-X5800
The specifications and functions of the control ports are as follows.
REMOTE 1 BNC 75
Z
Z
Z
Z
Z
Protocol : S-BUS control
Data Transfer Speed
312.5 kbps
Max Cable Length
500 m (BELDEN 8281 cable or equivalent)
Function : Control of the equipment is executed by the S-BUS data link.
The various types of equipment related to the control, such as remote control panel, routing
switcher, and display unit, are connected to this data link.
REMOTE 2 D-sub 9-pin
Protocol :
RS-422A
Transfer speed
38.4 kbps
Data bit
8 bits
Parity
EVEN
Protocol
Controllable size
16
x
x
x
x
x
16
256
x
x
x
x
x
256
4093
x
x
x
x
x
4093
CART
O
_
_
CART
+
O
O
_
CART
++
O
O
O
Function :
With this, the one-to-one port communication between two units is performed. It is used
when a Sony routing switcher is used as a simple matrix switcher when receiving controls
from the controller of other manufacturers via RS-422A.
RS-232C D-sub 9-pin
Protocol : RS-232C
Transfer speed
38.4 kbps
Data bit
8 bits
Parity
none
Check
none
Function : When connected with a personal computer, it performs program downloading and communi-
cation status monitoring.