3-8
BKS-R3219A/R1617A I&SSM
3-4. Setting Items of the Secondary
Station
Common Items
Name Display and Name Input Method:
Name displayed for the source or destination will automat-
ically switch depending on the state of the primary station
menu “J: NAME STYLE” is (Type
+
Num) or
(DESCRIP.NAM).
Compatibility of the Type
+
Num and DESCRIP.NAME
can be confirmed with “S: DISPLAY DESCRIPTION
NAME”. To use the description name, the terminal name
needs to be sent to the panel beforehand from "N: SET
DESCRIPTION NAME GROUP" in the primary station
menu.
When it is “Type
+
Number” name mode (Type
+
Num):
.
Name of destination or source is displayed by “Type
name
+
Number”.
.
Select the name from the type name list displayed at the
bottom of the screen and input the number using the
number key to change/modify the name.
When it is Description name mode (DESCRIP.NAME):
.
Name of destination or source is displayed by “Descrip-
tion” name.
.
Name can be set/changed by the same method as Type
+
Num (default), but it is possible to directly input the
description name using alphabet keys and number keys
by pressing
[Ctrl]
_
[N]
.
H : SET PHANTOM TABLE
Purpose
This menu is used to set PHANTOM which switchers
several crosspoints, using the source selection button of the
remote control unit.
The total number of cross-points that can be set to phantom
is 64.
Setting Procedure
1.
Select menu item of the secondary station [H].
2.
Select an item using the cursor, enter the phantom
name, the destination name and the source name.
3.
When
[Enter]
is pressed, the phantom table can be set.
If
[Enter]
is pressed before setting, the registration
will be deleted.
4.
Input the data to the phantom table. The phantom
function consists of the global phantom function regis-
tered at the primary station, the normal type of local
phantom function registered at each remote control unit
and the destination off set type of local phantom function.
.....
Setting the Global Phantom Function
Input the phantom name with the type name and the number.
Next, press
[G]
at destination name position. Lastly, input the
global phantom number (four digits) set at the primary station.
.....
Setting the Normal Type of Local Phantom
Function
1)
At [J : NAME STYLE (Type
+
Num)] in the
primary station menu item [J], input the type name
(between 0 and F) and the number for the phantom
name, destination name, source name and level
number respectively. (When the remote control unit
button is pressed, crosspoints with the same phan-
tom name will be switched together.)
2)
At [J : NAME STYLE (DESCRIP. NAME)] in the
primary station menu item [J], input the phantom name
and level number in the same way as 1). For the source
name and destination name, the Description name and
“Type
+
Number” name can be selected freely.
Each time
[Ctrl]
_
[N]
are pressed, the Description
name input mode (Crrl-N: DESCRIP. NAME) and
“Type
+
Number” name input mode (Crrl-N: Type
+
Num) will be switched alternately.