58
ADJUSTMENT
KD-60X690E/KD-70X690E(UC2/LA1)/KD-60X695E(AR4/LA8)/KD-60X697E(CO1)/KD-60X6700E/KD-70X6700E(AZ1/ME6/EA4)
HOW TO APPLY GAMMA/CUC/MURA with service board
Service Mode
1) Purpose: For After Service In The Market and Engineering Evaluation Purpose.
2) How to get into Service Mode
Push following keys sequentially.
Standby Mode
: <DISPLAY>, <5>, <VOL+>, <POWER>
Power ON Mode
: <LEFT>,<RIGHT>,<MUTE>,<OK/ENTER>,<MUTE>,<VOL+>
Service Mode
Status information .>>
Self diagnosis history >>
NO SIGNAL MUTE
TUNING SYSTEM
WIDE BAND TUNING
・・・・
・・・・
・・・・
LVDS SPREAD SPECTRUM (%)
LVDS Drive Strength (mA)
・・・・
・・・・
Panel/PQ
>>
BACK <<
WB Adjustment >>
WB/Mura/CUC data transfer >>
BACK <<
WB data transfer <[ 1.T-con To SoC ]>
MURA data transfer <[ 1.T-con To SoC ]>
CUC data transfer <[ 1.T-con To SoC ]>
[Start]
Description :
0. SoC to T-con
1. T-con to SoC
2. No Action
※
1. Select the Value 1 for each WB/MURA/CUC, then enter "Start" to execute data transfer.
2. Waiting 5 seconds.
3. AC Off/On
6/27 added