38
KDL-32L4000/37L4000
KDL-32L4000/37L4000
2-1. RESETTING THE TV TO THE FACTORY DEFAULTS
Traditional Service Mode is not available in this chassis. The only option for service technicians is to reset all of the settings to the Factory Default from
the Self Diagnostic screen.
CAUTION
: Resetting the TV to the Factory Defaults will
over-write all customer settings.
Before performing this reset, contact the customer to
determine what adjustments they have made.
1. TV must be in standby mode. (Power off).
2. Press the following buttons on the Remote Commander within a second of each other:
DISPLAY
Channel
5
Volume
+
TV POWER .
The Self Check list displays.
This is the SAME as accessing Self Diagnostic Function.
Results for all of the following diagnostic items are displayed at the bottom of the screen. No error has occurred if the screen displays a “0”.
QR0.5-C510
Model Information: 32L4000 8000001
ADC Auto Calibration
Power On Time: 00001H
SMPTE
ColorBar100
ITU 709
Gain
424
1020
420
1020
456
16
8
1840
128
1592
128
1608
424
1020
422
1020
460
16
Offset
Cr
Y
Cb
ITU 601
VGA
2:MAIN POWER 0 6:BL 0
3:DC ALERT1 0 7:TEMP 1
4:DC ALERT2 0 8:Audio 0
5:DC ALERT3 0
Gain
Offset
Gain
Offset
Factory Default
Indicates an error was detected
Indicates no error was detected
Model Information & Serial Number
Software Version
Power Time
Resets all settings
to the Factory Defaults
Diagnostic
List
Stored Data
from ADC calibration
(from factory)
3. From the Self Diagnostic screen, select
Factory Default
button and then select
Yes
.
4. To start Auto Program, select
Yes
.
NOTE: Allow 30+ minutes for Auto Program to complete.
5. Using the customers information, reset their adjustments.
SECTION 2: SERVICE ADJUSTMENTS