12
KDL-26L5000/32L5000
KDL-26L5000/32L5000
LED Indicators
Diagnostic Item
Description
Number of times
STANDBY lamp
flashes
Possible Location
Main Power
2 times
G2BE Board
Low B error
3 times
G2BE Board
A Board
T-CON power error
5 times
LCD Panel
Backlight error
6 times
LCD Panel
G2BE Board
Audio abnormal detection
8 times
A Board
Speaker(s)
1. TV must be in standby mode. (Power off).
2. Press the following buttons on the Remote Commander within a second of each other:
DISPLAY
Channel 5
Volume -
TV POWER
TV POWER .
The Self Check list displays.
This differs from accessing Service Adjustments.
Results for all of the following diagnostic items are displayed on screen. No error has occurred if the screen displays a “0”.
NOTE: If the Service Menu display text is not completely visible, press the Menu HOME button on the Remote Commander to refresh the display.
SELF CHECK
002 MAIN_POWER
001
�
1 indicates an error was detected
003 LOW B ERROR 1
000
�
0 indicates no error was detected
005 T-CON POWER ERROR
000
006 BACKLIGHT ERROR
000
008 AUDIO ABNORMAL DETECTOR
000
00001 00027 00009
�
������
Total Panel Hours
�
��
Total Hours of Operation
�
Boot Count
[Menu]Exit
BACK
3. To exit Self Check display, turn the power off. Press [Menu] Exit.
Clearing the Self Check Diagnostic List
1. In Service Mode, press the Channel 8
Channel 0.