Service Procedure for Panel, Board and Software Change / Upgrade(WW)
23
VPC
SERVICE
000
DATA_COPY
000
BU_TRANS
1
VPC Service menu
Press 2: increment
Press 5: decrement
Press 1: increment
Press 4: decrement
Press 3: increment
Press 6: decrement
VPC
SERVICE
000
DATA_COPY
000
BU_TRANS
2
DATA
TRANSFER
NG
VPC
SERVICE
000
DATA_COPY
000
BU_TRANS
3
DATA
TRANSFER
SUCCESS
NG
OK
This procedure is to copy W/B adjustment data in T-con board on Panel to BA* board.
Remote Commander
b
c
d
[To BU_TRANS of VPC]
a. Press the OPTIONS key to go to the VPC Service menu. (There are 3 Service menus “DIGITAL”
Æ
“CHASSIS”
Æ
“VPC”)
b. Press the “2/5” key on the remote commander to select 000 DATA COPY.
c. Press the “1/4” key on the remote commander to select 000 BU_TRANS.
d. Press the “3/6” key on the remote commander to select from 0 to 1. Data transfer will be done in few seconds.
1-7-9. Selecting the BU TRANS
SERVICE BOARD
Note: This procedure is necessary for KDL-**HX85* only.
OPTIONS