2-9 (E)
VPL-VW90ES
2-6-2. SUB CPU Upgrade
1. Double-click Flash.exe to start the application.
Application name: Main Flash Upgrader for Sony Projector
Execution
fi
le name: Flash.exe
Version:
1.05 or later
n
When starting the application
fi
rst, the following errors may appear. But, continue the procedure.
“No. 300: No information
fi
le was found.”
“No. 711: No download
fi
le was found.”
2. Click
the
[Select]
button for select download information
fi
le.
The
fi
le open window appears.
3. Select the download information
fi
le.
File to be selected: qhbv
****
.dli
(
****
means version number. Example: qhbv100a.dli)
4. Click
the
[Setting]
button of the “Com.”.
5. Set the following items.
Bit rate:
38,400 bit/s
Serial port: Serial port number used for connecting PC
Time
out:
Arbitrary
(Communication retrial time. default: 5 sec.)
6. Select “User Program Mode”.
7. Click
the
[Start]
button.
The start window appears.
8. Click
the
[OK]
button.
The “Please AC Plug In” window appears.
9. Connect the AC plug of this unit.
10. Check the Standby Mode is set to “Standard”. (Refer to Section 2-6-1 “Preparation”.)
11. Click the
[OK]
button.
The writing starts and the write window appear.
12. The end window appears. (Upgrade completed)
Summary of Contents for BRAVIA VPL-VW90ES
Page 1: ...VIDEO PROJECTOR VPL VW90ES REMOTE COMMANDER RM PJVW85 RM PJVW85J SERVICE MANUAL 1st Edition ...
Page 4: ......
Page 8: ......
Page 52: ......
Page 100: ......
Page 114: ......
Page 152: ......
Page 159: ...6 7 VPL VW90ES 6 7 GA GA 2 1 A B C D E F 3 4 G GA B SIDE SUFFIX 11 ...
Page 161: ...6 9 VPL VW90ES 6 9 GB GB GB B SIDE SUFFIX 11 2 1 A B C D E F 3 4 ...
Page 162: ......
Page 167: ......