31
HCD-M10
Flow Chart for Adjustment
YES
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
Start
IC195 replacement
OP or IC195 replacement
IC101, IC195 or D101
replacement
OP, IC190 or IC195
replacement
After turning the power off and on, initialises the non-volatile
memory (EEPROM).
7. Initial setting of adjustment value (See page 36)
9. Temperature compensation offset adjustment (See page 36)
10. Laser power adjustment (See page 36)
OP, IC102, IC190 or IC195
replacement
OP, IC101, IC151 or IC195
replacement
OP replacement
Spindle motor replacement
6-4. Auto check (See page 34)
End
11. Iop NV save (See page 37)
12.Traverse adjustment (See page 37)
13. Focus bias adjustment (See page 38)
16. Auto gain control output level adjustment (See page 39)
In Err display mode, write OP change iop
In Err display mode, Spdl change
•Abbreviation
OP: Optical pick-up