3-9
BVP-500
BVP-500P
Page
Ver.
Item
Settings
Contents
MATRIX
G-R, B-R
–99 to 99 (
[0]
)
Compensates the user’s matrix (sets an optional value as the constant
R-G, B-G
–99 to 99 (
[0]
)
for G-R, B-R, R-G, B-G, R-B and G-B).
R-B, G-B
–99 to 99 (
[0]
)
MATRIX
[ON]
, OFF
Turns the matrix compensation on and off.
USER
f )
[ON]
, OFF
Turns the user’s matrix compensation on and off.
PRESET
f )
[ON]
, OFF
Turns on and off only the preset matrix compensation (fixed constant
compensation).
TEST
1, 2,
[OFF]
Selects the test signal.
1
: Outputs the sawtooth waveform test signal
2
: Outputs 3-step form test signal
OFF : No test signal is output
CLEAR
Throw MENU SELECT
Sets all settings on the MATRIX page to 0.
switch to ENTER
(When you throw MENU SELECT switch to ENTER, the “CLEAR” indication
to execute.
flashes. Throw MENU SELECT switch to ENTER again to execute; throw to
CANCEL to cancel.)
SCENE FILE
1
Storing and recalling a scene file (painting data corresponding to a shot scene)
2
Storing a scene file
3
1 Turn MENU SELECT knob to move the
→
cursor to “FILE STORE,” then throw MENU SELECT
4
switch to ENTER. “FILE STORE” flashes on the viewfinder screen.
5
2 Select the file number (1 to 5) to be stored to.
FILE STORE
(If data is already stored at the selected location, the new data replaces the current data.)
Recalling a scene file
Turn MENU SELECT knob to move the
→
cursor to the file number whose data is to be
recalled, then throw MENU SELECT switch to ENTER.
• Every time MENU SELECT switch is pushed up to ENTER, the scene file data replaces the
current settings.
• When the scene file is recalled, an asterisk appears next to the number.
STANDARD
Returns the current amount of paint adjustments and switch setting to their reference value
stored as a reference file.
SHUTTER
1.10
SELECT
[OFF]
, SHUTTER,
Selects the shutter, EVS, or ECS mode.
EVS, ECS
1.10
SHUTTER
100
(or
60
),
125
,
250
,
Selects the shutter speed.
500
,
1000
,
2000
1.10
ECS
h)
Sets the ECS (CLS) frequency.
1.10
S-EVS
[0]
to 100%
Sets the desired resolution in %.
(This setting is invalid with the OHB-400/400P installed.)
OTHERS
1.09
16:9/4:3 MODE
[16:9]
, 4:3
Selects the aspect ratio for the video signal output.
i )
f )
When both USER and PRESET are set to ON, the matrix constant compensation is total value of the USER and PRESET matrix.
h)
Variable range differs depending on the OHB in use. For details refer to the operation manual supplied with the OHB.
i )
The aspect ratio normally corresponds to the CCU’s setting when the CCU is connected. To forcefully select, use this menu.
1
1
1
1
1
1
1
3-1. Setup Menu
3-1-2. Paint Menu
Summary of Contents for BVP-500
Page 14: ...1 6 BVP 500 BVP 500P 1 3 Outside Dimentions 1 3 Outside Dimentions Unit mm ...
Page 22: ...1 14 BVP 500 BVP 500P ...
Page 120: ......