5-13
BVP-500
BVP-500P
5-10. A/D Gain Adjustment
Equipment
: Waveform monitor
Test Point
: MONITOR connector
Preparations:
• Connect the waveform monitor to the MONITOR
connector.
• MASTER GAIN button/MSU operation panel
→
0 dB
• KNEE OFF button/MSU operation panel
→
OFF (Lights)
• DETAIL OFF button/MSU operation panel
→
OFF (Lights)
• GAMMA OFF button/MSU operation panel
→
ON (Stays out)
• MSU menu operation (Touch panel)
PAINT button
→
ON
∆
→
(Page 2/3)
→
WhiteClip
→
White Clip Off
(Reversed)
• S650 (MONITOR SELECT)/IF-538 panel
→
VF
• G button/rear panel
→
ON
Iris of the lens
: CLOSE
Adjustment Procedures
1.
Set the waveform monitor as follows.
• LUM mode
2.
Adjust the master black.
Adjustment Point
: MASTER BLACK control/
MSU operation panel
Specifications
: A = 3
±
1 IRE (for NTSC)
A = 21
±
7 mV (for PAL)
(Waveform Monitor)
3.
Adjust the auto black balance.
BLACK button/MSU operation panel
→
ON (Lights)
4.
TEST 2 button/MSU operation panel
→
ON (Lights)
5.
Set the DISPLAY switch/rear panel to MENU while
pushing up the MENU SELECT switch to ENTER.
6.
Set the menu as follows and adjust the A/D gain for G
using the MENU SELECT knob/switch.
Adjustment Point:
MENU
: System config
PAGE
: PR/VA/TEST (S3)
ITEM
: PR AD G [G]
Specifications
: The levels A and B shall be equal
when the color-bar signal is turned
on by setting the menu as follows.
MENU
: System config
PAGE
: Y/Chroma (S2)
ITEM
: CB
→
On
(For NTSC)
(For PAL)
5-10. A/D Gain Adjustment