background image

1

2

3

English

Condenser Microphone

Before using the microphone, please read this manual thoroughly. This manual should be 
retained for future reference.

FOR UNITED STATES CUSTOMERS. NOT APPLICABLE IN CANADA, INCLUDING IN THE 
PROVINCE OF QUEBEC.
POUR LES CONSOMMATEURS AUX ÉTATS-UNIS. NON APPLICABLE AU CANADA, Y 
COMPRIS LA PROVINCE DE QUÉBEC.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following 
two conditions: (1) this device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired 
operation.

You are cautioned that any changes or modifications not expressly approved in this 
manual could void your authority to operate this equipment.

The validity of the CE marking is restricted to only those countries where it is legally 
enforced, mainly in the countries EEA (European Economic Area).

Names and Functions of Parts (Fig.

)

(The numbers refer to the corresponding numbers in the figure.)

 

Microphone

 Directivity (Polar pattern) switch

: Uni-directional
: Omni-directional
: Bi-directional

 PAD switch

Select the PAD switch to the level of input source.

 :  Off

 : On

 LOW CUT switch

The low cut filter reduces the wind noise effectively.

 : Normal setting

 : The low cut filter is applied.

 Output connector (XLR-3-12C type)

The sound recorded with the microphone is output. The power is supplied to the 
microphone from an external equipment through this connector when the microphone 
is operating on the external power supply.

 Wind screen

Attach to the microphone 

 to reduce wind or breathing noise.

 Cradle suspension

When using a microphone stand (not supplied), for example, attach the cradle 
suspension to the microphone.
A stand adaptor is equipped to the cradle suspension. If you do not plan on using the 
stand adaptor, detach it, and then attach it to a microphone stand (sold separately).

 Ring

Be sure to rotate and fix the ring after the microphone is equipped to the cradle 
suspension. Unless done so, there is a risk the microphone will fall.

 Stand adaptor

Power Supply

This microphone is powered only from an external power supply. Connect output connector 

 of the microphone to the microphone connector of a Phantom power supply (external 

power supply) or an audio mixer. For connection, use a microphone cable.

Note

An unbalanced cable cannot be connected to this microphone. 

Be sure to use a balanced 

microphone cable.

How to open the carrying case (Fig.

)

Pull up the bottom hinge.*

Pull down the upper hinge.*

* Release the other hinge in the same way.

Push up the lid.

• 

When closing the carrying case, be careful that your hands, etc. are not caught in it.

• 

Do not place a heavy object or sit on the carrying case.

Notes on Use

• 

Microphones are delicate. Do not drop or subject it to excessive shock.

• 

Avoid extended usage or storage in high humidity or temperatures above 60 °C (140 °F). 
It may cause noise or failure.

• 

If acoustic feedback occurs during use (a howling sound is heard from the speakers), 
point the microphone away from the speakers or increase the distance between the 
microphone and the speakers.

• 

It takes a few minutes for the output voltage to stabilize after changing the directivity 
switch. 
Use it after the output is stabilized.

• 

The microphone output signal is a balanced output. Unbalanced output is not supported, 
so be sure to connect it to the balanced input circuit.

• 

Since the microphone adopts an extremely high impedance circuit, if the switch is 
changed while the external power is on, it may emit induction noise, but this is not a 
malfunction.

• 

The portion with “AUTO_PRESSURE_RELEASE” on the carrying case cannot be moved. 
Also, this does not guarantee its performance.

• 

A cable with the connector housing part connected to the ground wire (pin 1) is 
recommended for the microphone cable. 
Cables that are not connected to a ground wire may emit noise. 
If a ground terminal is available, noise can be reduced by connecting to that terminal. 
Also, if used extending several microphone cables and the connector housing part 
touches the floor, noise may worsen.

Specifications

General

Type 

2 Way Microphone (Con Electret condenser)

Power supply 

External power supply operation 44 V to 52 V DC (IEC* 61938 P48)

Power consumption 

Less than 4.5 mA

Output connector 

XLR-3-12C Type

Dimensions 

40 mm dia. × 175 mm (1.57 in. dia. × 6.89 in.)

Mass 

Approx. 290 g (10.2 oz)

Supplied accessories 

Cradle suspension (1) 
Wind screen (1) 
Stand adaptor (W3/8 - NS5/8) (1) 
Carrying case (1) 
Operating instructions (this sheet) (1) 
Warranty card (1)

Performance

Frequency response 

20 Hz - 50,000 Hz

Directivity 

Uni-directional / Omni-directional / Bi-directional (switchable)

Output impedance 

90 Ω ±15%, balanced

Sensitivity 

-31 dB (Uni-directional)

 

-37 dB (Omni-directional)

 

-35 dB (Bi-directional) 
(deviation±3 dB) 
(0 dB=1 V/Pa, 1 kHz)

Inherent noise 

Less than 19 dB SPL (Uni-directional)

 

Less than 24 dB SPL (Omni-directional) 
Less than 22 dB SPL (Bi-directional) 
(0 dB=2 × 10

-5

 Pa) 

(IEC* 61672-1 A-Weighted, 1 kHz, 1 Pa)

Maximum input sound pressure level   

More than 132 dB SPL (Uni-directional) 
More than 138 dB SPL (Omni-directional) 
More than 136 dB SPL (Bi-directional) 
(output level for 1% waveform distortion at 1 kHz, converted into 
equivalent input sound pressure level: 0 dB=2 × 10

-5

 Pa)

Dynamic range 

More than 113 dB (Uni-directional) 
More than 114 dB (Omni-directional) 
More than 114 dB (Bi-directional)

PAD 

0 dB/-10 dB (switchable)

LOW CUT filter 

Flat/70 Hz (switchable)

* IEC = International Electrotechnical Commission
Design and specifications are subject to change without notice.

Note

Always verify that the unit is operating properly before use. SONY WILL NOT BE LIABLE 
FOR DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION OR 
REIMBURSEMENT ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS DUE 
TO FAILURE OF THIS UNIT, EITHER DURING THE WARRANTY PERIOD OR AFTER EXPIRATION 
OF THE WARRANTY, OR FOR ANY OTHER REASON WHATSOEVER.

Condenser 

Microphone

Operating Instructions

GB

Mode d’emploi

FR

C-100

4-735-085-

12

(1)

©2018  Sony Corporation  Printed in Japan

http://www.sony.net/

Reviews: