51
Additional Information
Self-Diagnosis Function
The deck’s self-diagnosis function automatically checks the condition of the MD deck when an error
occurs, then issues a three-digit code and an error message on the display. If the code and message
alternate, find them in the following table and perform the indicated countermeasure. Should the problem
persist, consult your nearest Sony dealer.
Three-digit code/Message
Cause/Remedy
C11/Protected
The inserted MD is record-protected.
,
Take out the MD and close the record-protect slot (page 13).
C12/Cannot Copy
An attempt was made to play a disc that is not compatible with this deck
(MD data disc, etc.).
,
Replace the disc.
C13/Rec Error
The recording was not made properly.
,
Set the deck in a stable surface, and repeat the recording procedure.
The inserted MD is dirty (with smudges, fingerprints, etc.), scratched, or
substandard in quality.
,
Replace the disc and repeat the recording procedure.
C13/Read Error
The deck could not read the TOC on the MD properly.
,
Take out the MD and insert it again.
C14/Toc Error
The deck could not read the TOC on the MD properly.
,
Insert another disc.
,
If possible, erase all the tracks on the MD (page 29).
C41/Cannot Copy
The digitally dubbed material cannot be recorded digitally (page 11).
C71/Din Unlock
The sporadic appearance of this message is caused by the digital signal being
recorded. This will not affect the recording.
While recording from a digital component connected through the DIGITAL
(OPTICAL) IN connector, the digital connecting cable was unplugged or the
digital component turned off.
,
Connect the cable or turn the digital component back on.
E0001/MEMORY NG
There is an error in the internal data that the deck needs in order to operate.
,
Consult your nearest Sony dealer.
E0101/LASER NG
There is a problem with the optical pickup.
,
Consult your nearest Sony dealer.