15
Recording
Using the Digital Limiter and Digital Equalizer
To make recordings using the limiter and equalizer
effects, set the “SBM/LIMITER/EQ” control to
“L EQ” or “SBM + L EQ”. Make
detailed settings for each item using the Setup menu.
For operation details, refer to page 33, “Setup Menu
Operations”.
Digital Equalizer Setting
The CD recorder is equipped with a 3-band digital
equalizer, a shelving equalizer for bass and trable
frequency bands, and a parametric equalizer for
middle frequency band. Adjust the parameters to make
detailed settings using the Setup menu. For operation
details, refer to page 33, “Setup Menu Operations”.
Parameters and Variable Ranges
Bass frequency:
50 Hz to 1 kHz
Bass level:
_
6.0 dB to
+
6.0 dB
Mid frequency:
100 Hz to 10 kHz
Mid level:
_
6.0 dB to
+
6.0 dB
Mid width:
Wide/Mid/Narrow
Treble frequency: 1 kHz to 12.5 kHz
Treble level:
_
6.0 dB to
+
6.0 dB
z
Setting the band level parameter to high on the + side
may cause the signal level to rise to the clip level
internally, resulting in the sound warping. If this occurs,
lower the input level using the REC LEVEL control knob.
SBM/LIMITER/EQ
OFF
SBM
LIMITER
+
EQ
SBM
+
LIMITER
+
EQ
Treble equalizer
Frequency = 1 kHz, 12.5 kHz when each level = ±6 dB.
Mid equalizer
Frequency = 1 kHz and level = ±6 dB when width is
changed to 3 levels.
Equalizer Frequency Characteristics
Bass equalizer
Frequency = 50 Hz, 1 kHz when each level = ±6 dB.
Mid equalizer
Frequency = 100 Hz, 1 kHz, 10 kHz when each level =
±6 dB.
Recor
ding
Summary of Contents for CDR-W66
Page 39: ......