14
CFD-G55
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
AM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display
530 kHz
1,710 kHz
Reading on Digital voltmeter
1.0 ± 0.1 V
5.3 ± 0.8V
Adjustment Part
L 4
<confirmation>
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
CT3
620 kHz
1,400 kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.3 ± 0.4 V
3.0 ± 0.3 V
Adjustment Part
<confirmation>
L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
Adjustment Location : TUNER board (See page 16)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
TUNER SECTION
AM Section
Function switch : AM
FM Section
Function switch : FM
• Connecting Level Meter (FM and AM)
• Connecting Digital Voltmeter (FM and AM)
AM RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to
the set.
FM RF signal
generator
33.75kHz frequency deviation by
1kHz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01
µ
F
0dB = 1
µ
V
digital
voltmeter
100 k
Ω
TP CV
J391 (
i
)
set
32
Ω
level meter
(range: 0.5–5 V ac)
Summary of Contents for CFD-G55 - Cd Radio Cassette-corder
Page 26: ...26 26 CFD G55 5 10 Schematic Diagram MAIN Section 1 2 See page 34 for IC Block Diagrams ...
Page 29: ...29 29 CFD G55 5 13 Schematic Diagram AMP Section ...
Page 31: ...31 31 CFD G55 5 15 Schematic Diagram CONTROL Section ...
Page 33: ...33 33 CFD G55 5 17 Schematic Diagram POWER Section ...
Page 53: ...53 CFD G55 MEMO ...