10
CFS-929SMK2
Adjustment Location: See page 11
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455 kHz
MW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
516 kHz (EA model)
520 kHz (E15 model)
CT4
1,635 kHz (EA model)
1,680 kHz (E15 model)
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
600 kHz
CT3
1,400 kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
L9
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
87.35 MHz (EA model)
86.5 MHz (E15 model)
CT2
107.8 MHz (EA model)
109.5 MHz (E15 model)
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.35 MHz (EA model)
86.5 MHz (E15 model)
CT1
107.8 MHz (EA model)
109.5 MHz (E15 model)
SW1 FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L6
2.2 MHz
CT6
7.3 MHz
SW1 TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L5
2.2 MHz
< confirmation >
7.3 MHz
SW2 FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L8
6.8 MHz
CT8
22.5 MHz
SW2 TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L7
6.8 MHz
< confirmation >
22.5 MHz
TUNER SECTION 0 dB = 1 µV
Common Setting:
SOUND SELECT control: FLAT
VOLUME control: MAX
MAXI BASS switch: OFF
• MW Section
BAND switch: MW
FINE TUNING (RV2): mechanical center
• FM Section
BAND switch: FM
• SW1/SW2 Section
BAND switch: SW1 or SW2
FINE TUNING (RV2): mechanical center
• Common Connecting Level Meter
telescopic
antenna terminal
0.01
µ
F
FM RF signal
generator
75kHz frequency deviation
by 1kHz signal
Output level: as low as possible
set
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
400Hz, 30%
AM modulation
Output level: as low as possible
telescopic
antenna terminal
12pF
AM RF signal
generator
400Hz, 30%
AM modulation
Output level: as low as possible
set
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
PHONES jack (J301)
set
32
Ω
level meter
(range: 0.5–5 V ac)