– 8 –
Record/Playback Head Azimuth Adjustment
Procedure :
1. Mode : playback
2. Turn the adjustment screw for the maximum output levels. If
these levels do not match, turn the adjustment screw until both
of output levels match together within 3dB.
Phase Check
Mode : Playback
3. After the adjustment, lock the screw with locking compound.
Adjustment Location :
SECTION 4
ADJUSTMENTS
4-1. MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belt
capstan
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head demagnetizer close to the erase
head.)
3. Do not use a magnetized screwdriver for adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
Torque
Torque Meter
Meter Reading
Playback
CQ-102C
30 – 60 g • cm
(0.42 – 0.83 oz• inch)
Back Tension
CQ-102C
1 – 5 g • cm
(0.014 – 0.069 oz• inch)
Rewind
CQ-201B
more than 75 g • cm
Fast Forward
(more than 1.05 oz• inch)
Tape Tension Measurement
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 100g (3.53 oz)
4-2. ELECTRICAL ADJUSTMENTS
TAPE SECTION
1. The adjustments should be performed in the order give in the
service manual. (As a general rule, playbak circuit adjustment
should be completed before performing recording circuit adjust-
ment.)
2. The adjustments should be performed for both L-CH and R-CH
unless otherwise indicated.
• Switch location
FUNCTION switch
• • • • • • • • • • • • • • • •
TAPE (RADIO OFF)
PRESET MODE
• • • • • • • • • • • • • • • • • • • •
MANUAL
GRAPHIC EQUALIZER
• • • • • • •
center click
BALANCE
• • • • • • • • • • • • • • • • • • • • • • • • • • • •
center click
VOLUME
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
MAX
MEGA BASS
• • • • • • • • • • • • • • • • • • • • • • • •
mechanical center
KARAOKE MODE switch
• • • • •
OFF
Standard Output Level
Output terminal
PHONES
SP (FRONT) OUT
Load impedance
32
Ω
3.2
Ω
Output signal level
0.25V (–10dB)
0.775V (0dB)
Test Tape
Type
Signal
Used for
WS-48A
3kHz, 0dB
Tape Speed Adjustment
P-4-A063
6.3kHz, –10dB
Azimuth Adjustment
0dB=0.775V
set
L
R
test tape
P-4-A063
(6.3kHz, –10dB)
32
Ω
level meter
phones jack
L-CH
peak
R-CH
peak
L-CH
peak
R-CH
peak
Screw
position
output
level
within
3 dB
within
3 dB
screw position
L
R
in phase 45
°
90
°
135
°
180
°
good
wrong
set
L-CH
R-CH
screen pattern
level meter
phones jack
32
Ω
32
Ω
adjustment screw