3-7 (E)
CLX101ASA
3-2-6. Temperature Error
Is the temperature of the operating
environment within the specification?
Lower the temperature of the operating
environment.
When the error code is 315, replace the fan
on the right side.
When the error code is 316, replace the fan
on the left side.
Check if the air intake hole is not blocked.
If there is any foreign substance that blocks
the air intake hole, remove it.
(When the displayed error code is 110 or 310,
the error is eliminated.)
Is the displayed error code 315 or 316?
Yes
No
No
No
Yes
Replace the cell.
(The reading/writing of the data is also
necessary.
(
1)
)
Is the displayed error code 113 or 313?
Yes
Replace the UC-1 board.
(The reading/writing of the data is also
necessary.
(
2)
)
(
1):
Refer to the Manual for Color Uniformity Alignment Software,
Section 3-2.
(
2):
Refer to the Manual for Color Uniformity Alignment Software,
Section 3-3.
Is the displayed error code 111?
Yes
The following temperature error code is
displayed on the Display Control Software.
110, 111, 113
310, 313, 315, 316
End