5-23
13. Auto White Balance Check
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment
frame)
Measurement Point
Displayed data of
Video terminal
of Page: 1 (Note 2)
A/V OUT jack
(75
Ω
terminated)
Measuring Instrument
Adjustment remote Vectorscope
commander
Specified Value
R ratio:
Fig. 5-1-19
3E00 to 4200
(A) and (B)
B ratio:
3E00 to 4200
Note 1:
Refer to “Picture Frame Setting” for XH, XL, YH and
YL.
Note 2
: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Check that the lens is not
covered with either filter.
2
0
01
01
3
5
F1
FF
4
D
63
40
Press PAUSE button.
Perform “Data setting during
5
camera system adjustment”.
(Refer to page 5-13)
6
6
90
00
7
6
91
04
8
6
92
00
9
6
93
30
10
6
6C
01
11
6
2C
01
12
6
01
79
Press PAUSE button.
13
Wait for 3 seconds.
INDOOR data check
14
E
52
Note down the data.
15
E
52
1A
Press PAUSE button.
16
6
01
0F
Press PAUSE button.
17
0
03
04
Check that the displayed data
18
1
(Note 2) satisfied the R ratio
specified value.
19
0
03
05
Check that the displayed data
20
1
(Note 2) satisfied the B ratio
specified value.
INDOOR luminance point check
21
0
03
00
Check that the center of the
22
white luminance point within
the circle shown Fig 5-1-19 (A).
OUTDOOR luminance point check
23
Place the C14 filter on the lens.
24
E
4B
Note down the data.
25
E
4B
20
Press PAUSE button.
26
6
01
3F
Press PAUSE button.
Check that the center of the
27
white luminance point settles
in the circle shown Fig 5-1-19
(B).
28
6
90
XL
(Note 1)
29
6
91
XH
(Note 1)
30
6
92
YL
(Note 1)
31
6
93
YH
(Note 1)
32
6
6C
01
33
6
2C
01
34
6
01
79
Press PAUSE button.
35
Wait for 3 seconds.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
6C
00
3
E
4B
Set data noted down at step 24,
and press PAUSE button.
4
E
52
Set data noted down at step 14,
and press PAUSE button.
5
6
2C
00
6
5
F1
00
7
D
63
00
Press PAUSE button.
Release the data setting
8
performed at step 5.
(Refer to page 5-13)
9
0
01
00
R-Y
B-Y
4 mm
4 mm
R-Y
B-Y
1.5 mm
1 mm
6 mm
6 mm
Fig. 5-1-19 (A)