DSC-P9
5-22
11. Auto White Balance 3200K Check
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data
Video terminal of
of Page: 1
A/V OUT jack
(Note 2)
(75
Ω
terminated)
Specified Value
R ratio: 3FA0 to 4060
B ratio: 3FA0 to 4060
R-Y level data: 7E to 82
B-Y level data: 7E to 82
Y level data: 10 to 40
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame
setting”. (WIDE end)
(Refer to page 5-15)
3
6
B6
Note down the data.
4
6
B6
03
5
7
5D
Note down the data.
6
7
5D
00
Press PAUSE button.
7
7
9D
Note down the data.
8
7
9D
80
Press PAUSE button.
9
6
37
0D
10
6
01
11
Press PAUSE button.
11
6
38
Check the data changes to
“01”.
12
6
01
C1
Press PAUSE button.
13
6
02
Check the data changes to
“01”.
14
0
03
04
15
1
Check that the displayed data
(Note 2) satisfied the R ratio
specified value.
16
0
03
05
17
1
Check that the displayed data
(Note 2) satisfied the B ratio
specified value.
18
0
03
2C
19
1
Check that the R-Y level data
(Note 2) satisfied the
specified value.
20
0
03
2D
21
1
Check that the B-Y level data
(Note 2) satisfied the
specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
7
5D
Set data noted down at step
5, and press PAUSE button.
3
7
9D
Set data noted down at step
7, and press PAUSE button.
4
0
03
00
5
6
37
00
6
6
B6
Set data noted down at step
3, and press PAUSE button.
7
F
74
Check that the displayed data
76
the Y level specified value.
7C
7E
84
86
8
Release the data setting
performed at step 1.
(Refer to page 5-14)