DSC-P9
5-30
20. Strobe White Balance Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance when the strobe light flashed.
Mode
CAMERA
Subject
Flash adjustment box (Note 3)
Paper which reflection rate is
18% (Note 6)
(50 cm from the front of lens)
Measurement Point
Displayed data of page: 1 (Note
4) and page: F, address: E8, EA,
EC, EE
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
B6, B7, DB to EF
Specified Value
Y level data: 07 to 10
R-Y level data:
007A to 0086 (Note 4)
B-Y level data:
007A to 0086 (Note 4)
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Perform this adjustment in the Flash adjustment box.
Note 3:
Refer to “4. Preparing the Flash adjustment box”.
(See page 5-7)
Note 4:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Note 5:
“Strobe White Balance Adjustment” is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Note 6:
Background paper (J-2501-130-A).
Switch setting:
1) FLASH (Control button) .............. ON
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame
setting”. (Refer to page 5-15)
3
4
1E
Note down the data.
4
4
1E
00
5
6
2C
01
6
6
90
00
7
6
91
00
8
6
92
FF
9
6
93
FF
10
6
6C
01
11
6
01
79
Press PAUSE button.
12
6
07
Check the data changes to
“01”.
13
6
01
67
Press PAUSE button.
14
Check the flashing.
15
6
02
Check the data changes to
“01”.
Order Page Address Data
Procedure
16
F
E8
Check that the displayed data
satisfies the Y level specified
value.
17
6
01
00
Press PAUSE button.
18
6
90
E0
19
6
91
01
20
6
01
79
Press PAUSE button.
21
6
07
Check the data changes to
“01”.
22
6
01
67
Press PAUSE button.
23
Check the flashing.
24
6
02
Check the data changes to
“01”.
25
6
01
00
Press PAUSE button.
26
6
90
00
27
6
91
00
28
6
01
79
Press PAUSE button.
29
6
07
Check the data changes to
“01”.
30
6
01
67
Press PAUSE button.
31
Check the flashing.
32
6
02
Check the data changes to
“01”.
33
6
01
00
Press PAUSE button.
34
6
01
67
Press PAUSE button.
35
Check the flashing.
36
6
02
Check the data changes to
“01”.
37
6
01
00
Press PAUSE button.
38
6
01
B9
Press PAUSE button. (Note 7)
39
Check the flashing.
40
6
02
Check the data changes to
“01”.
41
6
01
00
Press PAUSE button.
42
6
01
E7
Press PAUSE button.
43
Check the flashing.
44
6
02
Check the data changes to
“01”.
EA
Check that the displayed data
45
F
EC
satisfies the Y level specified
EE
value.
46
0
03
2C
47
1
Check that the R-Y level data
(Note 4) satisfies the specified
value.
48
0
03
2D
49
1
Check that the B-Y level data
(Note 4) satisfies the specified
value.
Note 7:
The adjustment data will be automatically input to page:
F, address: B6 to B7 and DB to EF.