DSC-P9
5-38
9.
White Balance Adjustment (SW-368 Board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on the LCD screen
Measuring Instrument
Adjustment Page
A
Adjustment Address
88, 89
Specified Value
LCD screen must not be colored
Note 1:
Check the white balance only when replacing the fol-
lowing parts. If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC801
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
02
03
Press PAUSE button
3
4
F1
02
4
A
88
94
Press PAUSE button.
(Initial value)
5
A
89
7A
Press PAUSE button.
(Initial value)
6
Check that the LCD screen is
not colored. If not colored,
proceed to “Processing after
Completing Adjustments”.
7
A
88
Change the data so that the
LCD screen is not colored.
89
(Note 2)
Note 2:
To write in the non-volatile memory (EEPROM), press
the PAUSE button each time to set the data.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
A
02
00
Press PAUSE button
2
4
F1
00
3
0
01
00