DSC-QX10
4-8
(2) DC Motor Worm Assy Replacing Method
Claws
Sensors
FG Leaf
Spring
Claw
FPC Retainer
Z Retainer
Removal
1. Disengage the two claws and remove the FG Leaf Spring.
2. Remove the two Sensors.
3. Disengage the claw and remove the FPC Retainer.
4. Disconnect the two flexible boards from the connectors on the LF-139 Flexible Board.
5. Peel off the FPC Tape.
6. Remove the LF-139 Flexible Board.
7. Remove the four screws and remove the Z Retainer and the Sensor.
8. Detach the Rear Mirror Plate and remove the Gear Worm Wheel, Gear A, and Gear B.
9. Remove the two screws and remove solder at two locations to detach the DC Motor Worm Assy.
Gear A
Gear B
Gear Worm
Wheel
Ribs
Rib
Rib
Rib
Boss
Boss
Screws
Screws
Screw
Sensor
Boss
Boss
Flexible board
LF-139 Flexible Board
LF-139 Flexible Board
Flexible board
FPC Tape
Connector
Connector
Rear Mirror
Plate
DC Motor Worm Assy
Solders