1-4
DCR-SR90E/SR100/SR100E_L2
ENGLISH
ENGLISH
1-4. PROCESS AFTER FIXING FLASH ERROR
When “FLASH error” (Self-diagnosis Code E:91:**) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is
changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Connect the adjustment remote commander and perform the following process.
Order Page Address Data
Procedure
1
7
01
75
2
7
00
01
Press PAUSE button.
3
7
02
Check the data changes to “01”.
1-5. PRECAUTION ON REPLACING THE VC-449 BOARD
Exif Model Data Check
When you replace to the repairing board, the written data of repairing board also might be changed to original setting.
When the data has changed because of board replaceing etc, check the data setting (Exif Model Data) is right. If not, rewrite to the right value.
Exif Model Data
Writing Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: A, address: B6 to B9, and set the Exif Model Data.
Note:
To write in the non-volatile memory (EEPROM), press the PAUSE (Write) button each time to set the data.
3) Select page: 0, address: 01, and set data: 00.
Page
A
A
A
A
Data
DCR-SR100
31
30
30
00
DCR-SR90E
39
30
45
00
DCR-SR100E
31
30
30
45
Address
B6
B7
B8
B9