1-2
DCR-HC1000/HC1000E
2.
POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V), the power is shut off so
that the unit cannot operate.
This following two methods are available to prevent this. Take note of which to use during repairs.
Method 1.
Use the AC power adaptor.
Method 2.
Connect the servicing remote commander RM-95 (J-6082-053-B) to the LANC jack, and set the commander switch to the “ADJ” side.
3.
TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT)
1
Remove the grip block section, cabinet (L).
2
Remove the grip block section from the cabinet (L).
3
Remove the grip (bottom) cabinet from the grip block section.
4
Remove the grip (R) cabinet assembly from the grip block section.
5
Remove the grip hinge assembly from the grip block section.
6
Disconnect CN2502 (27P, 0.3mm) of RP-241 board.
7
Open the cassette lid.
8
4.5V from the DC power supply to the loading motor and unload with pressing the cassette compartment.
ENGLISH
JAPANESE
ENGLISH
JAPANESE
Loading motor
DC power supply
(+ 4.5Vdc)
Disconnect the flexible board
from CN2502 of RP-241 board
CN2502
RP-241 board
Summary of Contents for DCR-HC1000 - Digital Handycam Camcorder
Page 3: ... 3 DCR HC1000 HC1000E ENGLISH JAPANESE ENGLISH JAPANESE 5 18 ...
Page 5: ... 5 DCR HC1000 HC1000E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 13: ...1 6 DCR HC1000 HC1000E SECTION 1 SERVICE NOTE ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 14: ...1 7 DCR HC1000 HC1000E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 15: ...1 8 DCR HC1000 HC1000E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 16: ...1 9 DCR HC1000 HC1000E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 17: ...1 10E DCR HC1000 HC1000E ENGLISH JAPANESE ENGLISH JAPANESE ...
Page 91: ...5 18 5 REPAIR PARTS LIST 5 REPAIR PARTS LIST DCR HC1000 HC1000E J MODEL ...
Page 100: ...ENGLISH JAPANESE ENGLISH JAPANESE ...