1-2
DCR-HC65
2.
POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V), the power is shut off so
that the unit cannot operate.
This following two methods are available to prevent this. Take note of which to use during repairs.
Method 1.
Use the AC power adaptor (AC-L25).
Method 2.
Connect the servicing remote commander RM-95 (J-6082-053-B) to the LANC jack, and set the commander switch to the “ADJ” side.
3.
TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT)
1
Open the flash.
2
Remove the cabinet (F) section.
3
Remove the cabinet (R) section.
4
Remove the EVF section.
5
Remove the VC-359 board.
6
Remove the mechanism deck.
7
4.5V from the DC power supply to the loading motor and unload with pressing the cassette compartment.
VC-359
VC-359 board
DC power supply (+4.5Vdc)
Loading motor