5-34
DCR-IP45/IP45E/IP55/IP55E
1-4.
COLOR ELECTRONIC VIEWFINDER
SYSTEM ADJUSTMENT
Note1:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note3:
When performing the viewfinder system adjustments with the
cabinet (R) removed, perform the following data setting before
the adjustments. (This data setting will be canceled, when the
automatic adjustment is done.)
1) Select page: 3, address: 00, set data: 01 and press PAUSE
button.
2) Select page: 3, address: 02, and set data: 02.
Reset the data after completing adjustment.
1) Select page: 3, address: 00, set data: 00 and press PAUSE
button.
2) Select page: 3, address: 02, and set data: 00.
Switch setting:
LCD panel ...................................................... Closed (Note3)
[Measuring points]
The measuring points for manual adjustment are Pin
eg
(EXT DA)
of IC2201 of DI-085 board and Pin
qg
(G) of CN3602 of VF-154
board.
Fig. 5-1-15.
Fig. 5-1-16.
25
36
37
48
1
12
13
24
IC2201
DI-085 board
(SIDE A)
CN3602
16
1
VF-154 board (SIDE B)