6-12
Checking method:
1) Place the Siemens star 2.0m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the Siemens
star up to a point before noise appears on the image.
3) Set data: 02 to page: 6, address: 40.
4) Set data: 01 to page: 6, address: 41.
5) Shoot the siemens star with the zoom TELE end.
6) Turn on the auto focus.
7) Check that the lens is focused (Note 1), and turn off the auto
focus
8) Set data: 10 to page: 6, address: 21.
9) Shoot the siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is focused.
Note 1:
When the auto focus is ON, the lens can be checked if it is
focused or not by observing the data on page A of the
adjusting remote commander.
1) Set data: 0F to page: 6, address: 04.
2) Page A shows the state of the focus.
A : 00 : XX
01: Focused
00: Unfocused
Processing after Completing Adjustments
1)
Set data: 00 to page: 6, address: 21.
2)
Set data: 00 to page: 6, address: 04.
3)
Set data: 00 to page: 6, address: 40.
4)
Set data: 00 to page: 6, address: 41.
6-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Adjusting Method:
1) Set the IRIS to open. (Use a ND filter)
2) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away (subjects with clear contrast such as
buildings, etc.). (Nearby subjects less than 500 m away should
not be in the screen.)
3) Set data: 01 to page: 6, address: 00.
4) Check that the data of page: 6, address: 02 is “00”.
5) Set data: 13 to page: 6, address: 01, and press the PAUSE button
of the adjusting remote commander.
6) Set data: 29 to page: 6, address: 01, and press the PAUSE button
of the adjusting remote commander.
(Adjustment data will automatically be input to page: F, addresses:
24 to 29, 38 to 3C.)
7) Check that the data of page: 6, address: 02 is “01”.
Processing after Completing Adjustments
1) Set data: 00 to page: 6, address: 00.
2) Turn OFF the main power supply (8.4V).
3) Perform “Flange Back Check”.
Subject more than 500m away
(In case of a subject less than 500m
away, that should be subjects with clear
contrast such as most distant buildings,
etc.)
Adjustment Page
Adjustment Address
F
24 to 29, 38 to 3C
Subject
7. Flange Back Check
Subject
Measurement Point
Measuring Instrument
Specified Value
Check the operation on the TV monitor
Focused at the TELE end and WIDE
end.
Siemens star
2.0m from the front of the lens
Luminance: approx. 200 lux
n
Summary of Contents for DCR-PC7
Page 41: ...6 2 Fig 6 1 1 J 1 J 2 J 3 J 4 J 5 J 6 J 7 J 8 J 9 J 10 J 11 ...
Page 92: ...6 57 ...
Page 95: ...6 60 ...
Page 96: ...6 61 ...
Page 97: ...6 62 ...
Page 104: ... 282 Sony EMCS Co DCR PC7 PC7E 9 973 919 11 2006I0500 1 2006 9 Published by Kohda TEC ...