6-47
3-5. VIDEO SYSTEM ADJUSTMENTS
3-5-1. RF Block Adjustments
1. Recording Current Adjustment (MR-36 Board)
A
0.1
µ
sec
VTR stop
Mode
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
ODDch adjustment
CH1: Pin
5
of CN2708 (CL2719)
CH2: Pin
6
of CN2708 (CL2718)
EVENch adjustment
CH1: Pin
2
of CN2708 (CL2722)
CH2: Pin
3
of CN2708 (CL2721)
Oscilloscope
ADD mode
CH2 INV mode
C
3E, 3F
A = 3.1 ± 0.1 Vp-p
Connection: Disconnect CN2708 and connect as follows.
1) ODDch adjustment: Connect a 180
Ω
resistor between Pin
5
of
CN2708 (CL2719) and Pin
6
of CN2708 (CL2718).
2) EVENch adjustment: Connect a 180
Ω
resistor between Pin
2
of CN2708 (CL2722) and Pin
3
of CN2708 (CL2721).
180
Ω
resistor (Parts code: 1-249-408-11)
Adjusting method:
1) Equalize the vertical range of CH1 and CH2 of the oscilloscope.
2) Set the oscilloscope to the ADD mode, and set CH2 to the INV
mode.
3) Set data: 01 to page: 1, address: 00.
4) Set data: 0C to page: 3, address: 01, and press the PAUSE button
of the adjusting remote commander.
5) Set data: 01 to page: 3, address: 34.
6) Change the data of page: C, address: 3F (ODDch adjustment) or
address: 3E (EVENch adjustment), and adjust the signal voltage
(A) to the specified value, press the PAUSE button on the
adjustment remote commander.
7) Set data: 04 to page: 3, address: 34.
8) Set data: 00 to page: 3, address: 01, and press the PAUSE button
of the adjusting remote commander.
9) Set data: 00 to page: 1, address: 00.
Fig. 6-3-6.
2. PLL fo Adjustment (MR-36 Board)
Mode
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
VTR stop
Display data of page: 3, address: 04
C
3D, 3C
Displayed data is “FD” to “FF”,
“00” to “03”.
(“FF”, “00” are center values)
Adjusting method:
1) Set data: 01 to page: 1, address: 00.
2) Set data: 05 to page: 3, address: 01, and press the PAUSE button
of the adjusting remote commander.
3) Set data: 04 to page: 3, address: 36.
4) Check that the average value D
04
of the displayed data of page:
3, address: 04 is “FD” to “FF”, “00” or “03”. If outside this
range, change the data of page: C, address: 3C, and check again.
[If D
04
is “80” to “FC”]
Decrease the data of page: C, address: 3C. (As the data is to be
rewritten, press the PAUSE button of the adjusting remote
commander.)
[If D
04
is “04” to “7F”]
Increase the data of page: C, address: 3C. (As the data is to be
rewritten, press the PAUSE button of the adjusting remote
commander.)
5) Set data: 05 to page: 3, address: 36.
6) Check that the average value D
04
of the displayed data of page:
3, address: 04 is “FD” to “FF” or “00” to “03” . If outside this
range, change the data of page: C, address: 3D, and check again.
[If D
04
is “80” to “FC”]
Decrease the data of page: C, address: 3D. (As the data is to be
rewritten, press the PAUSE button of the adjusting remote
commander.)
[If D
04
is “04” to “7F”]
Increase the data of page: C, address: 3D. (As the data is to be
rewritten, press the PAUSE button of the adjusting remote
commander.)
7) Set data: 00 to page: 3, address: 01, and press the PAUSE button
of the adjusting remote commander.
8) Set data: 02 to page: 3, address: 36.
9) Set data: 00 to page: 1, address: 00.
Summary of Contents for DCR-PC7
Page 41: ...6 2 Fig 6 1 1 J 1 J 2 J 3 J 4 J 5 J 6 J 7 J 8 J 9 J 10 J 11 ...
Page 92: ...6 57 ...
Page 95: ...6 60 ...
Page 96: ...6 61 ...
Page 97: ...6 62 ...
Page 104: ... 282 Sony EMCS Co DCR PC7 PC7E 9 973 919 11 2006I0500 1 2006 9 Published by Kohda TEC ...