5-24
DCR-TRV40/TRV40E/TRV50/TRV50E
5. CCD Output 2ch Matching Adjustment (2)
Correct the dispersion between the left-right channels of the CCD
imager.
Subject
Clear chart (All white) (Note1)
Adjustment Page
F
Adjustment Address
29 to 2D
Note1:
Shoot the clear chart with the zoom TELE end.
Note2:
This adjustment should be carried out upon completion of the
following adjustments.
CCD Output 2ch Matching adjustment (1)
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
19
Write down the data.
3
F
19
C0
Set the data.
4
6
2C
01
Set the data.
5
6
40
01
Set the data.
6
6
01
F5
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“00” in about 50 seconds after
pressing PAUSE button.
8
F
19
Set the data that is written down
at step 2, and press PAUE
button.
Note4:
The adjustment data will be automatically input to page: F, address:
29 to 2D
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
2C
00
Set the data.
3
6
40
00
Set the data.
4
0
01
00
Set the data.
6. MR Adjustment
The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
58, 5A to 65
Specified Value1
40 to C0
Specified Value2
03 to 78
Specified Value3
88 to F8
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
Perform this adjustment before “Flange Back Adjustment”.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
BD
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note5)
4
F
5A
Check that the data satisfies the
specified value 1.
5
F
5B
Check that the data satisfies the
specified value 1.
6
F
5C
Check that the data satisfies the
specified value 1.
7
F
5D
Check that the data satisfies the
specified value 1.
8
F
5E
Check that the data satisfies the
specified value 2.
9
F
5F
Check that the data satisfies the
specified value 3.
10
F
60
Check that the data satisfies the
specified value 2.
11
F
61
Check that the data satisfies the
specified value 3.
12
F
62
Check that the data satisfies the
specified value 2.
13
F
63
Check that the data satisfies the
specified value 3.
14
F
64
Check that the data satisfies the
specified value 2.
15
F
65
Check that the data satisfies the
specified value 3.
Note5:
The adjustment data will be automatically input to page: F, address:
58, 5A to 65.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.