Signal Name Failure
Appears when the display of signal
names is enabled for multi-view
output, and the signal name
display data cannot be sent.
Reset the settings of the output
video, and try turning the display of
signal names off and on again
Status was modified
Status was because boards
were different modified
Appears when data is recalled
under the following conditions, if
the sources specified for
parameters cannot be selected
because the configuration of
currently installed option boards
differs from the board configuration
at the time when the data was
saved.
• Reading system data when
starting a control panel
• Executing Recall All Data or
Recall System Data to recall
system data from a USB flash
drive
• Recalling a sequence
• Recalling an event
When this error occurs,
parameters that specify sources
which cannot be selected are set
to BLK.
Install option boards in the same
configuration as when the data
was saved, and then execute the
recall again.
Update Failure
Appears when an update fails.
Try executing the update again.
Wipe No. reserved
Appears when no wipe pattern is
registered for the selected number.
Select another pattern.
Message
Description
Action to take
Display panel
GUI menu screen
Summary of Contents for DFS-900M
Page 189: ...189 Pattern List Appendix Pattern List Wipe Basic wipe ...
Page 190: ...190 Pattern List Appendix User wipe ...
Page 191: ...191 Pattern List Appendix Mask ...
Page 193: ...193 Pattern List Appendix ...
Page 194: ...194 Pattern List Appendix 3D DME effects ...
Page 195: ...195 Pattern List Appendix ...
Page 196: ...196 Pattern List Appendix User effects ...
Page 216: ...216 External Dimensions Appendix BKDF 902 1 5M E Control Panel Unit mm inches ...
Page 217: ...217 External Dimensions Appendix DFS 900M Processor Unit Unit mm inches ...