1-6-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R1401 in the periphery of IC6800 on the VC-1025 board, turn the power
ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect the camera
control circuit (IC6000 of VC-1025 board) periphery.
Note:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-6-2. E : 62 : 11 [Shift Lens Overheating (Pitch)] Occurred
Order
Procedure
1
Start the Adjust Manual in the Adjust Station and execute the [Measure to E:62:11/12] on the [SERVICE] tab.
2
Check if the shift lens moves while setting the order 1.
If the shift lens does not move, replace the lens block (Note).
When the shift lens moved, proceed to the order 3.
3
While setting the order 1, measure with an oscilloscope the output voltage of C6816 and C6817 in the periphery of IC6800 on the VC-
1025 board to check the output voltage varies.
4
If the output voltage does not vary, replace the lens block (Note).
When the output voltage varied, proceed to the order 5.
5
Turn the power OFF.
6
While measuring with an oscilloscope the output voltage of R1401 in the periphery of IC6800 on the VC-1025 board, turn the power
ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
7
If the output voltage rises to 3V, replace the lens block (Note).
If it does not rises to 3V, inspect the camera control circuit IC6000 and IC6800 on the VC-1025 board periphery.
Note:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-6-3. E : 62 : 12 [Shift Lens Overheating (Yaw)] Occurred
Order
Procedure
1
Start the Adjust Manual in the Adjust Station and execute the [Measure to E:62:11/12] on the [SERVICE] tab.
2
Check if the shift lens moves while setting the order 1.
If the shift lens does not move, replace the lens block (Note).
When the shift lens moved, proceed to the order 3.
3
While setting the order 1, measure with an oscilloscope the output voltage of C6814 and C6815 in the periphery of IC6800 on the VC-
1025 board to check the output voltage varies.
4
If the output voltage does not vary, replace the lens block (Note).
When the output voltage varied, proceed to the order 5.
5
Turn the power OFF.
6
While measuring with an oscilloscope the output voltage of R1401 in the periphery of IC6800 on the VC-1025 board, turn the power
ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
7
If the output voltage rises to 3V, replace the lens block (Note).
If it does not rises to 3V, inspect the camera control circuit IC6000 and IC6800 on the VC-1025 board periphery.
Note:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-6-4. E : 62 : 20 [Abnormality of Thermistor] Occurred
Order
Procedure
1
Turn the power ON.
2
Confirm the connections of flexible flat cables and connectors between the lens block and VC-1025 board.
3
In case of no malfunction of connections, replace the lens block with new one (Note) . When the error has occurred in spite of the lens
replacement, replace VC-1025 board with new one.
Note:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-7. NOTE ON REPLACING PROJECTOR UNIT (Projector Model)
Refer to the following flowchart when repairing or inspecting the projector’s projection function.
If you have received an indication on the projector’s projection function from the customer, check defective part according to the following flow-
chart.
When a defective part has been clarified, repair the projector according to the check result.
Note 1:
The projector unit (copper plate in particular) becomes hot after it is used.
When replacing a part of the projector unit, wait until it is cooled down.
Wipe the lens gently with a soft cloth such as a cleaning cloth or glass cleaning cloth.
Note 2:
Stubborn stains may be removed with a soft cloth such as a cleaning cloth or glass cleaning cloth lightly dampened with water.
Never use a solvent such as alcohol, benzene or thinner; acid, alkaline or abrasive detergent; or a chemical cleaning cloth, as they will damage the lens sur-
face.
Projector problem checking procedure (other than indication on brightness)
Indicated defective
projector received
Measure brightness.
( 2)
Yes
No
OK
OK
NG
NG
OK
NG
A
B
Indication on
brightness
Inspect projector
LED.
( 1)
1 Refer to the ADJUST tab of Adjust Manual.
2 Refer to the SERVICE tab of Adjust Manual.
Inspect projector
LED.
( 1)
END
-
-
-
-
-
Replace projector unit (light emitting block). (
*
1)
Replace PJ board. (
*
1)
Replace both projector unit (light emitting block)
and PJ board. (
*
1)
Projector Data Input
Fixed value input
Enter the number on the label attached to the unit.
Serial number input
LD40
Syywwnnnnn