1-5 (E)
DSM-T1
1-7. Rack Mounting
1-7. Rack Mounting
The DSM-T1 can be mounted in a 19-inch standard rack.
m
.
If the DSM-T1 or the peripheral equipment are mounted
in a 19-inch standard rack, it is recommended to install a
ventilation fan to prevent a temperature rise in the rack.
Make sure that all the units in the rack should be
operated within the temperature range of 0
d
C to 40
d
C.
.
Connect the enough long cables on the rear panel,
considering that the DSM-T1 is pulled out.
.
To prevent falling the rack, fix it on the horizontal firm
floor with bolts.
Required parts
.
Rack Mount Kit, RMM-30 (Option)
or
RACK-MOUNT SLIDES, Model 305A
Manufactured by Accuride
Slide length 558.8 mm (22 inch)
c
Be sure to use the specified rack mount rail.
If a rack mount rail other than the specified one is used, the
DSM-T1 may be dropped by insufficient strength of the
rack mount rail. This may cause a injury.
The following parts are supplied with the DSM-T1.
.
Rack angle (1U) Assembly : 2 pcs.
.
Rail bracket
: 4 pcs.
.
Screw (K 4
x
14)
: 4 pcs.
.
Screw (B 4
x
14)
: 4 pcs.
.
Screw (B 4
x
8)
: 8 pcs.
.
Screw (B 5
x
12)
: 8 pcs.
.
Screw (RK 5
x
14)
: 4 pcs.
.
Plate nut (small)
: 4 pcs.
.
Plate nut (large)
: 4 pcs.
.
Spring washer ø5
: 8 pcs.
.
Washer ø5
: 8 pcs.
.
Washer ø4
: 4 pcs.
.
Ornamental washer
: 4 pcs.
Procedures
1.
Turn the power of the DSM-T1 off.
2.
Remove the four feet from the bottom of the DSM-T1.
3.
Attach the inner rails to the DSM-T1 using the screws
(K 4
x
14).
4.
Attach the rack angle (1U) assemblies to the DSM-T1
using the screws (B 4
x
14) and washers (ø4).
Feet
Feet
B 3
x
10
B 3
x
10
Washers ø4
Washers ø4
Rack angle
(1U) assemblies
B 4
x
14
B 4
x
14
Inner rails
K 4
x
14
K 4
x
14