Attaching the Viewfinder to a Camera

6

Attaching the Viewfinder 
to a Camera

Depending on the version of your PMW-F5/F55, an 
image may not be displayed.
In such cases, contact a Sony service representative.

Attach this unit to the camera using the supplied flexible 
arm.
This unit has a total of three flexible arm attachment 
points at the top, bottom, and rear of the unit. Select an 
attachment point based on your intended use.

Top attachment point

Bottom attachment point

Rear attachment point

This section describes how to attach the flexible arm to 
the top of the unit as an example.

• Hold both the viewfinder and the flexible arm firmly 

when performing attachment or detachment.
In addition, the flexible arm may move at its joints if the 
arm lock knob is loose. Take care not to drop the 
viewfinder and flexible arm.

• Fixing screws are located on both ends of the flexible 

arm. Confirm the camera end and the viewfinder end, 
and perform attachment using the proper ends.
Camera attachment point: Includes edges that fit the 
camera’s handle.
Viewfinder attachment point: Includes a positioning 
pin.

1

Attach the flexible arm to the camera.

1

Align the screw on the flexible arm’s camera 
attachment point with screw hole (1/4-20UNC) on 
top of the camera’s handle.
Make sure the camera attachment point is oriented 
correctly in relation to the handle.

Note

Notes

1

2

Arm lock knob

Camera 
attachment point

Summary of Contents for DVF-L700

Page 1: ...LCD Color View Finder 4 460 309 13 1 2013 Sony Corporation Operating Instructions Before operating the unit please read this manual thoroughly and retain it for future reference DVF L700 ...

Page 2: ... Contents Overview 3 Usage Notes 3 Parts Identification 4 Attaching the Viewfinder to a Camera 6 Detaching the Viewfinder 7 Adjusting the Position 8 Adjusting the Display 8 Error Messages 9 Cleaning the Screen 9 Specifications 10 ...

Page 3: ...u turn on the power Condensation If the unit is suddenly taken from a cold to a warm location or if ambient temperature suddenly rises moisture may form on the outer surface of the unit and or inside of the unit This is known as condensation If condensation occurs turn off the unit and wait until the condensation clears before operating the unit Operating the unit while condensation is present may...

Page 4: ...llows you to adjust the tally indicator s brightness Set this to OFF when you are not using the tally indicator HIGH Increases the brightness LOW Decreases the brightness OFF Turns the indicator off nFOCUS MAG magnified display button Magnifies the height and width of the image x2 for easier focus adjustment This does not affect the camera s output signal The FOCUS MAG indicator lights during magn...

Page 5: ...n the camera using a BNC cable For details on supported formats see Specifications page 10 u minus button Use this after pressing the BRIGHT CONTRAST or PEAKING button to change the respective value v plus button Use this after pressing the BRIGHT CONTRAST or PEAKING button to change the respective value wPEAKING adjustment button Allows you to emphasize the outlines in the image This does not aff...

Page 6: ...he viewfinder and the flexible arm firmly when performing attachment or detachment In addition the flexible arm may move at its joints if the arm lock knob is loose Take care not to drop the viewfinder and flexible arm Fixing screws are located on both ends of the flexible arm Confirm the camera end and the viewfinder end and perform attachment using the proper ends Camera attachment point Include...

Page 7: ...r s VF connector and the angle connector to the camera s VF connector Verify the orientations of the connectors and insert them until they click into place 2 Set the INPUT SELECT switch to the VF position Be sure to check the shape of the VF connection cable s connector and insert it in the proper orientation For use in monitor mode 1 Use a BNC cable to connect the viewfinder s SDI IN connector to...

Page 8: ... knob in the LOCK direction to lock it into place The three joints of the flexible arm will be locked into place Adjusting the Display You can adjust the brightness contrast and peaking of the display using the BRIGHT CONTRAST and PEAKING buttons When using VF mode changing the peaking value with the PEAKING button will not affect the display image unless the peaking setting on the camera is enabl...

Page 9: ...Do not use thinner or other solvents After use in harsh environments Be sure to perform the following maintenance after using the viewfinder at dusty locations beaches hot springs or other harsh environments Use an airbrush to carefully remove any dust or sand from inside the viewfinder Clean the contacts of the connectors After performing the above maintenance perform a basic operation test and c...

Page 10: ...0 cd m2 typical Resolution 1920 1080 Color temperature D65 Unit mm inches 127 5 194 7 3 4 52 2 1 8 Supported formats during HD SDI connection Total number of scanning lines 1125 Number of effective scanning lines 1080 Horizontal resolutions of 2048 are not supported VF 26 pin rectangular type 1 SDI IN BNC type 1 MONITOR OUT BNC type 1 DC IN 4 pin 1 10 5 V to 17 0 V DC Before Using this Unit 1 Oper...

Page 11: ... OF PRESENT OR PROSPECTIVE PROFITS DUE TO FAILURE OF THIS UNIT EITHER DURING THE WARRANTY PERIOD OR AFTER EXPIRATION OF THE WARRANTY OR FOR ANY OTHER REASON WHATSOEVER SONY WILL NOT BE LIABLE FOR CLAIMS OF ANY KIND MADE BY USERS OF THIS UNIT OR MADE BY THIRD PARTIES SONY WILL NOT BE LIABLE FOR THE TERMINATION OR DISCONTINUATION OF ANY SERVICES RELATED TO THIS UNIT THAT MAY RESULT DUE TO CIRCUMSTAN...

Page 12: ...Sony Corporation ...

Reviews: