7-1
SECTION 7
ELECTRICAL ADJUSTMENT
DVP-F21
In making adjustment, refer to 7-4. Adjustment
Related Parts Arrangement.
Note:
During diagnostic check, the characters and color bars
can be seen only with the NTSC monitor. Therefore, for
diagnostic check, use the monitor that supports both
NTSC and PAL modes.
Use the reference disc for PAL for check, and use the
reference disc for NTSC for adjustment.
This section describes procedures and instructions necessary for
adjusting electrical circuits in this set.
Instruments required:
1)
Color monitor TV
2)
Single or dual trace oscilloscope, band width over 100 MHz,
with delay mode
3)
Frequency counter (over 8 digits)
4)
Digital voltmeter
5)
Standard commander (RMT-D126A/D126E/D126P)
6)
DVD reference disc
HLX-501 (J-6090-071-A) (dual layer) (NTSC)
HLX-503 (J-6090-069-A) (single layer) (NTSC)
HLX-504 (J-6090-088-A) (single layer) (NTSC)
HLX-505 (J-6090-089-A) (dual layer) (NTSC)
HLX-506 (J-6090-077-A) (single layer) (PAL)
HLX-507 (J-6090-078-A) (dual layer) (PAL)
7)
SACD reference disc
HLXA-509 (J-6090-090-A)
8)
Extension Cable (J-6090-107-A)
7-1. POWER SUPPLY CHECK
1. MB-99 Boards
Mode
E-E
Instrument
Digital voltmeter
1
EVER +3.3 V Check
Test point
JL708
Specification
3.3
±
0.1 Vdc
2
SW +3.3 V Check
Test point
JL710
Specification
3.3
±
0.2 Vdc
3
+5 V Check
Test point
JL709
Specification
5.0
±
0.3 Vdc
4
SW +11 V Check
Test point
JL706, JL707
Specification
10.5
±
0.5 Vdc
5
EVER +5 V Check
Test point
JL711
Specification
5.0
±
0.2 Vdc
6
SW –11 V Check
Test point
JL705
Specification
–11.0
±
1.0 Vdc
7
+1.8 V Check
Test point
JL713
Specification
1.8
±
0.1 Vdc
Checking method:
1)